Description
About – Paxton Net2 I/O board plastic housing consists of four inputs and outputs which connects directly to a LAN/WAN via an onboard RJ45 connector. I/O boards can be distributed around a building as required. Inputs and outputs can be controlled using the Net2 software ‘triggers and actions’ feature. Boards can be supplied as PCB only, in a plastic housing or mounted within a 2A boxed metal/plastic mains monitored backup power supply.
Installation – A label clearly shows the connections. The Paxton Net2 I/O board is fitted with the same rising clamp connectors as the Net2 control unit.
Operation – Inputs and outputs are configured using the Net2 software triggers and actions feature.
System specifications –
Inputs – 4
Relay outputs – 4
Electrical –
Operating Voltage – 10V – 14V DC
Current consumption – 400mA
Relay contact current rating – 13A
Relay contact isolation – 4kV AC
Relay contact voltage – 240V AC
Relay contact frequency – 50Hz
Communication
TCP/IP – Yes
Wireless – No
RS485 – No
Ethernet network speed – 100Mbit/s auto MDIX
Ethernet bandwidth requirement – 200 kbits/sec
DHCP support (fixed IP recommended) – Yes
Environment
Operating temperature – -20°C – +55°C / -4°F – +131°F
Moisture resistance – No – if used externally, it must be protected in a weatherproof housing.
Vandal Resistance – No
Installation instructions available here.
Find out more about us here.