Description
Paxton Part no 682-531
About – Net2 is a networked access control system. A networked system gives the advantages of central control, event reporting and flexible control over users’ access. Each control unit is part of a network but can run independently making its own decisions and remembering events.
The Net2 plus control unit connects to the central administration PC using an RJ45 plug into a standard TCP/IP Ethernet network. This greatly increases the flexibility of installation options on sites that have LAN/WAN networks. The Net2 plus control unit also has a RS485 connection. This means it can be connected to other Net2 plus or Net2 classic control units using a dedicated CAT5 cable.
One Net2 plus control unit can be the network interface to the LAN and also run a wired RS485 daisy chain of other Net2 plus or Net2 classic units, removing the need for an independent TCP/IP to RS485 converter. Net2 plus is also available with a Power over Ethernet (PoE) power supply. PoE is a technology that allows both power and data to be passed along Ethernet cabling. Net2 plus with PoE simply plugs straight into the existing LAN using a standard RJ45 plug (providing it is powered by either a compatible PoE switch or a PoE injector).
Control units are sold as a PCB only, within a plastic housing or mounted within a 2A boxed metal/plastic mains monitored backup power supply. The Net2 plus unit now comes with PoE+ power supply in metal/plastic cabinet; no separate mains supply back-up required.
Box contents
· Connector – 2 way plug UL |
· Connector – 3 way plug UL |
· Connector – 4 way plug UL |
· Connector – 5 way plug UL |
· Connector – 6 way plug UL |
· Connector – 8 way plug UL |
· Fasteners – 15mm PCB spacer 1.6mm board |
· Fitting kit – ACU with PSU in cabinets & housings |
· Label – 682-531 ratings label |
· Label – product serial number label 27x10mm |
· Label – Tech support international |
· Label – Void if seal is broken, 80x30mm |
· Sales Code label, 27x20mm, Paxton EX, CE, Ctick |
· Net2 Plus access control unit V2 |
· Cable tie Large |
· Net2 International Wiring Label Assy |
· 2A plastic cabinet assy with PSU |
Specifications – Net2 plus 1 door controller – 12V 2A PSU, Plastic cabinet | ||||
min | typ | max | units | |
Electrical | ||||
Voltage supplied by Paxton 2A PSU | 13 | 13.8 | 14 | V DC |
Current capacity of Paxton 2A PSU | 2000 | mA | ||
Operating voltage | 11 | 24 | V DC (+20%) | |
Current consumption | 200 | mA | ||
Switchable current | 4 | A | ||
Switchable voltage | 24 | V DC (+20%) | ||
Alarm output current | 1 | A @ 12 V DC | ||
Environment | ||||
Operating temperature – Battery limits | 0 | 45 | °C | |
Moisture resistance | None | |||
System Specification | ||||
Max number of wireless ACUs per system | 1000 | |||
Number of card holders | 50000 | |||
Number of PINs | 50000 | |||
PIN length | 4 | 8 | digits | |
Number of codes | 50 | |||
Code length | 4 | 8 | digits | |
Readers/keypads per door | 2 | per port | ||
Door open time | 1 | 7 | 999999 | sec |
Time zones | 64 | |||
Individual times within a time zone | 2000 | |||
Number of events stored on ACU | 2728 | |||
Data retention during power loss | 30 | day(s) | ||
Can be used with fail OPEN release | Yes | |||
Can be used with fail CLOSED release | Yes | |||
Exit button input | Yes | |||
Door contact input | Yes | |||
Alarm/bell output | Yes | |||
PSU monitoring input | Yes | |||
Tamper input | Yes | |||
Intruder alarm integration input | Yes | |||
Wiring | ||||
Reader cable type | Belden 9540 | |||
RS485 data line | CAT5 or Belden 8723 | |||
Max RS485 data line length | 1000 | m | ||
Max number of ACU’s per RS485 data line | 200 | |||
TCP/IP connection | Yes | |||
Max TCP/IP nodes | 200 | |||
Ethernet network speed | 10 | 100 | Mbps | |
Ethernet bandwidth required | 9 | 115 | 200 | kbps |
DHCP support | Yes (static IP recommended | |||
Modem support | Yes | |||
Dimensions – Control unit | ||||
Width | 116 | mm | ||
Height | 126 | mm | ||
Depth | 25 | mm | ||
Dimensions – 2A PSU in plastic cabinet | ||||
Width | 232 | mm | ||
Height | 320 | mm | ||
Depth | 80 | mm |